The SCKit campaign didn't need malware delivery in the usual sense. Commands arrived through the MSP's own ScreenConnect instance, ran as SYSTEM on managed endpoints, and installed a second ScreenConnect client that phoned home to the attacker. To most EDR baselines that looks like what an MSP does all day: the remote support agent spawning cmd.exe and installing software. If your detections allowlist the RMM agent as a trusted parent, this campaign ran underneath them.
This post walks through what Microsoft and Huntress documented about SCKit, then gives you detections that key on what an attacker can't avoid: a second remote support client pointing somewhere new, persistence written by the toolkit, and the browser cookie theft aimed at technicians. It's written for SOCs inside MSPs and for internal teams whose endpoints are managed by one.
What happened
On November 11, 2026, ConnectWise reported an active campaign against cloud-hosted ScreenConnect instances belonging to managed service providers. Huntress saw the first suspicious activity at about 17:47 UTC that day and counted at least 288 affected endpoints across 48 of its customer organizations, all hit within 90 minutes and roughly a third in the first ten minutes. ConnectWise disabled five third-party extensions (Labtech Plus, RMM Plus, RMM+, RMM Plus Password Link and RMM+ Password Link) across about 400 partner environments as a precaution, according to Cybersecurity Dive and The Record.
The initial access route is still unconfirmed by ConnectWise. Huntress's leading candidate is the RMM+ extension, which lets callers manage sessions without a technician signing in to the console and authenticates requests with a shared access key instead of ScreenConnect accounts, roles or MFA. In RMM+ versions 1.0.31 and 1.0.32, if that key was never configured, the extension accepted a blank one, and blank was the default. Huntress also noted commands reaching endpoints with no matching console logins. Treat RMM+ as the likely path, not a proven one, and keep credential theft and hijacked operator sessions on the list.
Microsoft Threat Intelligence published the most complete breakdown of the toolkit on November 13. Neither Microsoft nor Huntress has named a threat actor.
The attack chain
- Mass Run Command. The operator used ScreenConnect's command feature to push commands to many endpoints at once. They run as SYSTEM, started by the ScreenConnect client.
- Rogue client install.
cmd.exerunscurl.exeto fetch/Bin/ScreenConnect.ClientSetup.msifrom an attacker-run ScreenConnect server, saves it asC:\Windows\Temp\sc.msiand installs it silently with/i /qn /norestart. The installer URL carries a custom property of the formc=Exploited<N>. - Dropper and decoder. PowerShell decodes a Base64 batch file into
C:\Windows\Temp\sckit-run.bat, which downloads a decoder fromns[.]mo7sen[.]dev/EadF.phpintosckit-decoder.ps1and runs it with-Mode full. The decoder derives its key from the host'sMachineGuid, decrypts an AES-256-CBC bundle and unpacks it to%TEMP%\SCKitBundle. - Trap install. The kit lands in
C:\ProgramData\RelayTrap, registers aTrapWatchscheduled task running as SYSTEM, adds a machine-wide Run value namedRelayTrapLiteAlert, writes SRP/AppLocker rules that stop files pushed through ScreenConnect's temp folders from running, adds Defender exclusions and installs a second attacker ScreenConnect client. - RelayTrap. TrapWatch compiles
RelayTrap.cswith the .NET C# compiler intoC:\ProgramData\RelayTrap\trapbins\<client id>\RelayTrap.exe. RelayTrap is built from the customer's own ScreenConnect client libraries and connection details, and it takes over the legitimate client's connection slot, so the endpoint still looks normal in the MSP console. - Technician targeting. When a technician connects to a trapped endpoint, RelayTrap tries to push a batch launcher back through the session to run on the technician's workstation. On a technician machine, the kit hunts for
.ASPXAUTHsession cookies in Chrome, Edge, Opera and Opera GX, decrypting them through DPAPI or scraping them from browser network-service process memory. - Spread.
ToolboxRelayUploader.exeuses a stolen technician session to join sessions as Host, upload a payload to the Shared Toolbox, queue it on every session the technician can reach, and delete it about 60 seconds later.
Steps 6 and 7 are the worm design. Huntress says the endpoint-to-technician and technician-to-console spread had not been seen succeeding in any host log it recovered, and Microsoft describes the propagation path as design rather than a confirmed chain of infections. Plan for it anyway: the code exists, and a single success hands the attacker every customer the technician can reach.
Microsoft, citing ConnectWise, says the fix for CVE-2026-84869 blocks the endpoint-to-technician file transfer that RelayTrap relies on, and ConnectWise recommends technician clients on 26.6.5 or later. Updating the cloud console doesn't update the clients technicians run, so check client versions on technician workstations directly.
Where SCKit leaves evidence
| Stage | Telemetry | What to look for |
|---|---|---|
| Rogue client install | Process events, Sysmon EID 1 | ScreenConnect client → cmd.exe → curl.exe fetching ScreenConnect.ClientSetup.msi; msiexec installing sc.msi from Windows Temp |
| Second remote support client | Process events, software inventory | More than one ScreenConnect relay host on the same device |
| Persistence | Registry, file and process events | RelayTrapLiteAlert Run value, TrapWatch task, files under C:\ProgramData\RelayTrap, Defender exclusions for Temp or CWInstall_ paths |
| On-host compilation | Process events | The C# compiler run by PowerShell as SYSTEM against a .cs file in ProgramData |
| Cookie theft | Process events, EDR memory-access alerts | sqlite3.exe on a workstation, .ASPXAUTH in a command line, DPAPI and browser memory access alerts |
| Infrastructure | Network, DNS, proxy | The domains and IPs in the IOC section below |
Detection 1: The RMM agent installing another RMM agent
This is the alert to put in production. A ScreenConnect client spawning a shell is normal for an MSP. That shell downloading and installing a ScreenConnect installer is not, because legitimate client updates come through the product's own update path rather than curl.exe and msiexec from Windows Temp.
let lookback = 14d; DeviceProcessEvents | where TimeGenerated > ago(lookback) | where InitiatingProcessFileName =~ "ScreenConnect.ClientService.exe" or InitiatingProcessParentFileName =~ "ScreenConnect.ClientService.exe" | where FileName in~ ("curl.exe", "msiexec.exe", "powershell.exe", "pwsh.exe", "bitsadmin.exe", "certutil.exe") | where ProcessCommandLine has_any ("ScreenConnect.ClientSetup", "/Bin/ScreenConnect", "c=Exploited", "sc.msi", "sckit", "EadF.php") or (FileName =~ "msiexec.exe" and ProcessCommandLine has @"\Windows\Temp\" and ProcessCommandLine has "/qn") | project TimeGenerated, DeviceName, AccountName, FileName, ProcessCommandLine, InitiatingProcessFileName, InitiatingProcessCommandLine, InitiatingProcessParentFileName | order by TimeGenerated desc
The SCKit-specific strings (c=Exploited, sckit, EadF.php) are cheap to keep but will rotate. The durable part is the behavior: a remote support agent pulling down a remote support installer. False positives come from MSPs that deliberately deploy a second ScreenConnect instance through Run Command during a migration. Allowlist those by the destination host in the URL, not by parent process. If you're on Defender XDR advanced hunting rather than Sentinel, swap TimeGenerated for Timestamp.
The Sysmon version for Splunk follows the same logic:
index=sysmon EventCode=1 earliest=-14d (ParentImage="*\\ScreenConnect.ClientService.exe" OR ParentImage="*\\cmd.exe") (Image="*\\curl.exe" OR Image="*\\msiexec.exe" OR Image="*\\powershell.exe") (CommandLine="*ScreenConnect.ClientSetup*" OR CommandLine="*/Bin/ScreenConnect*" OR CommandLine="*c=Exploited*" OR CommandLine="*\\Windows\\Temp\\sc.msi*" OR CommandLine="*EadF.php*") | table _time, host, User, ParentImage, ParentCommandLine, Image, CommandLine | sort - _time
Point index and the field names at however your Sysmon data is mapped. The cmd.exe parent arm catches the second hop, where the ScreenConnect client starts cmd.exe and cmd.exe starts curl.exe; it's broader, so keep the installer strings in that arm.
Detection 2: Devices talking to more than one ScreenConnect relay
The end state of SCKit is a device with an extra remote support client, and in some cases two. That's an inventory question, and you can answer it from process telemetry. The ScreenConnect client service command line carries the relay host it connects to in an h= parameter. Check the format against one of your own clients before you rely on the regex below; it's the part of this query most likely to need adjusting for your build.
let lookback = 30d; let approved_relays = dynamic(["yourmsp.screenconnect.com", "relay.yourmsp.com"]); // your instances DeviceProcessEvents | where TimeGenerated > ago(lookback) | where FileName =~ "ScreenConnect.ClientService.exe" | extend RelayHost = tolower(extract(@"[?&]h=([^&""\s]+)", 1, ProcessCommandLine)) | where isnotempty(RelayHost) | summarize Relays = make_set(RelayHost, 10), FirstSeen = min(TimeGenerated), LastSeen = max(TimeGenerated) by DeviceName | extend Unapproved = set_difference(Relays, approved_relays) | where array_length(Relays) > 1 or array_length(Unapproved) > 0 | order by array_length(Unapproved) desc
Run it unfiltered first. Most organizations discover a handful of relay hosts they didn't know about: a vendor's support instance, a previous MSP's leftover client, a user who installed a support client for a third party. Each one is a remote access path you should know about, so the initial cleanup is worth doing even outside this campaign. Once the approved list is accurate, any new unapproved relay is a high-severity alert. The same approach works for AnyDesk, Atera and other tools if you extend the file name list.
Detection 3: SCKit persistence
The toolkit's persistence uses fixed names in the versions documented so far. Hunt them together, because one artifact on its own can be cleaned up and the others left behind.
let lookback = 30d; union (DeviceRegistryEvents | where TimeGenerated > ago(lookback) | where ActionType == "RegistryValueSet" | where (RegistryKey has @"\CurrentVersion\Run" and (RegistryValueName =~ "RelayTrapLiteAlert" or RegistryValueData has "RelayTrap")) or (RegistryKey has @"\Windows Defender\Exclusions\Paths" and RegistryValueName has_any (@"\Windows\Temp", "ConnectWiseControl", "CWInstall_", "RelayTrap")) | extend Evidence = strcat(RegistryKey, " | ", RegistryValueName, " = ", RegistryValueData), Source = "registry"), (DeviceFileEvents | where TimeGenerated > ago(lookback) | where FolderPath has @"\ProgramData\RelayTrap" or FileName in~ ("RelayTrap.cs", "RelayTrap.exe", "TrapWatch.ps1", "ToolboxRelayUploader.exe", "Panel-Lateral.ps1", "sckit-run.bat", "sckit-decoder.ps1", "RELAY-TRAP-PROOF.txt") | extend Evidence = strcat(FolderPath, " (", ActionType, ")"), Source = "file"), (DeviceProcessEvents | where TimeGenerated > ago(lookback) | where ProcessCommandLine has_any ("TrapWatch", "RelayTrap", "-PollSeconds") | extend Evidence = ProcessCommandLine, Source = "process") | project TimeGenerated, DeviceName, Source, Evidence, InitiatingProcessFileName, InitiatingProcessCommandLine | order by TimeGenerated desc
This is a sweep, not a durable rule: Huntress points out that the scripts are rebuilt with different embedded values and RelayTrap is compiled per host, so hashes and names are weak. The Defender exclusion arm is the part to keep long term. Exclusions for Windows Temp or ScreenConnect's own install folders should never come from anything except your management tooling.
Detection 4: Compiling code on the endpoint
Compiling RelayTrap on the host is a choice that helps the attacker dodge hash-based detection, and it leaves a behavior that's rare in most fleets: the .NET Framework C# compiler started by a script host running as SYSTEM, with output written to ProgramData.
let lookback = 30d; DeviceProcessEvents | where TimeGenerated > ago(lookback) | where FileName =~ "csc.exe" | where InitiatingProcessFileName in~ ("powershell.exe", "pwsh.exe", "cmd.exe", "wscript.exe", "cscript.exe") | where ProcessCommandLine has_any (@"\ProgramData\", @"\Windows\Temp\", @"\AppData\Local\Temp\") | project TimeGenerated, DeviceName, AccountName, ProcessCommandLine, InitiatingProcessFileName, InitiatingProcessCommandLine | order by TimeGenerated desc
PowerShell's Add-Type also calls csc.exe under the hood, so you'll see legitimate scripts that compile small helpers into the user's temp folder. Developer workstations and build servers will be noisy too. Scope those out by device group, and give hits that run as SYSTEM or write to ProgramData a higher severity than per-user temp compiles.
Detection 5: Technician cookie theft
The technician workstation is where SCKit stops being an endpoint problem and becomes an MSP-wide one. The kit reads browser cookie databases with a bundled copy of the SQLite command-line tool and looks specifically for the ScreenConnect web session cookie.
let lookback = 30d; DeviceProcessEvents | where TimeGenerated > ago(lookback) | where FileName =~ "sqlite3.exe" or ProcessCommandLine has ".ASPXAUTH" or (ProcessCommandLine has_any ("Cookies", "Network\\Cookies") and ProcessCommandLine has_any ("Local State", "sqlite")) | project TimeGenerated, DeviceName, AccountName, FileName, FolderPath, ProcessCommandLine, InitiatingProcessFileName, InitiatingProcessCommandLine | order by TimeGenerated desc
Developers and DBAs use sqlite3.exe legitimately, so check the folder path: a copy running out of a temp or ProgramData folder on a technician's workstation is very different from one in a developer's tools directory. Pair this with Defender's own alerts, which catch the memory-scraping route better than command lines do. Microsoft lists "Possible theft of passwords and other sensitive web browser information" and "Suspicious DPAPI Activity" among the alerts it saw fire on this activity, alongside "Suspicious command execution via ScreenConnect", "Suspicious installation of remote management software" and "Suspicious Microsoft Defender Antivirus exclusion". If those alerts are tuned down for your technician workstations because remote support tooling is noisy, revisit that.
Infrastructure and IOCs
Microsoft and Huntress published matching network indicators. Run them across your full retention, not just 14 days, because the infrastructure may have been staged earlier.
let lookback = 90d; let domains = dynamic(["ns.mo7sen.dev", "sc.payproofkit.com", "newnewnew.gotdns.org", "soxnewwork.homedns.org", "cdn007-digitaldownloads.com"]); let ips = dynamic(["185.99.255.28", "155.94.150.39"]); DeviceNetworkEvents | where TimeGenerated > ago(lookback) | where RemoteUrl has_any (domains) or RemoteIP in (ips) | summarize Connections = count(), FirstSeen = min(TimeGenerated), LastSeen = max(TimeGenerated), Processes = make_set(InitiatingProcessFileName, 10) by DeviceName, RemoteUrl, RemoteIP, RemotePort | order by FirstSeen asc
Huntress notes the RelayTrap source names soxnewwork.homedns.org as a relay on port 81, which is an unusual port for a ScreenConnect relay and worth a standing firewall rule. Both write-ups also list SHA-256 hashes for the toolkit files; pull them from the original posts rather than copying them secondhand, and expect them to age quickly.
Response
If any of the detections above hit, assume the MSP's ScreenConnect instance is the delivery channel and act accordingly.
- Don't triage through ScreenConnect. Both Huntress and Microsoft are explicit: investigate infected hosts through EDR live response or another out-of-band path. A technician connecting to a trapped endpoint is exactly what RelayTrap is waiting for.
- Isolate, and widen the scope to technicians. Isolate affected endpoints and include every technician workstation that connected to them. Check those workstations for the cookie theft behavior and for a rogue ScreenConnect client of their own.
- Preserve the console records. Keep Run Command, Toolbox, extension and authentication logs from the ScreenConnect instance before anything is rotated. Toolbox history matters because the uploader deletes its item after broadcasting it.
- Revoke sessions, then rotate. From a clean device, revoke ScreenConnect web sessions and the related identity provider sessions, then rotate credentials. Microsoft notes that a password change alone doesn't kill an existing session cookie.
- Remove persistence completely. That means the rogue client services, the
TrapWatchtask,C:\ProgramData\RelayTrap, theRelayTrapLiteAlertRun value, the Defender exclusions and the SRP/AppLocker rules the kit added. Confirm the legitimate client is identified before you remove anything. Microsoft advises against using the kit's own cleanup scripts, and its decoder can re-arm after cleanup. - Watch for reinfection. Huntress saw systems reinfected shortly after isolation was lifted. Keep Detection 1 and Detection 3 at high severity for those hosts for several weeks.
Hardening that actually closes the path
- Keep the five extensions disabled until you've confirmed a fixed version and a business need. If you run RMM+ at all, set a strong
RMMPlus.AccessKey; a blank default is the problem Huntress describes. - Update technician clients, not just the console. Verify each technician workstation runs ScreenConnect 26.6.5 or later.
- Inventory remote access tools against an approved list. Detection 2 is the start. Application control that only allows your approved remote support binaries, signed by the expected publisher and pointing at your relays, removes the rogue client step entirely.
- Stop treating the RMM agent as a trusted parent. Exclusions that suppress alerts for anything the RMM agent spawns are exactly what this campaign relied on. Narrow them to specific scripts and command lines.
- Protect the technician browser. Technicians should reach the ScreenConnect console from a hardened, dedicated browser profile or admin workstation with tamper protection, cloud-delivered protection and the credential theft alerts above all enabled.
SCKit is a reminder that the most trusted agent on an endpoint is also the most useful one to an attacker. The fix isn't to stop trusting remote support tools; it's to know exactly which instances your devices are allowed to talk to, alert the moment one points somewhere else, and keep technician workstations at the same security tier as domain admins. If you can answer "which ScreenConnect relays do our devices connect to?" with a query today, you're ahead of most environments this campaign touched.